SITRANS Probe LUProduct Focus

SITRANS Probe LU
2 Wire Ultrasonic transmitter for Level and Flow Measurement.

2-wire, loop powered ultrasonic transmitter for level, volume, and flow. Highly intelligent with single push button obstruction avoidance and HART & Profibus options, ideal for devolved measurement into existing or new control solutions. With the highest of Ingress protection the LU Probe is a low cost solution suitable for a wide variety of applications. ATEX and 6m and 12m range options.

Innovative Solutions Include ..

The appraisal of the technical capability of an instrumentation and measurement company and it's engineering, is the combination of their knowledge, experience, and skills displayed in their ability to select, install, commission and test the most appropriate and effective instrumentation and measurement system that ..

Read More >>

Latest News

3 in a Row with Scottish Water

Processplus are pleased to announce their third consecutive term in support of Scottish Water's ongoing capital program, 2010-2015. In partnership…

Read More >>

Transit Time Ultrasonic

Enquire View Downloads
Transit Time Ultrasonic Image

Our range of ultrasonic multipath ?time of flight? flow meters are suitable for the continuous monitoring of rivers, canals, open channels and large partially full pipes. They are Velocity x Area meters using wetted multipath ultrasonic time of flight transducers for velocity and either wetted or through air ultrasonic level transducers.

Application areas:

  • Water resource management
  • Flood prediction
  • Abstraction control
  • Effluent monitoring
  • Sewage plant control
  • Hydroelectric power generation
  • Irrigation
  • Leak detection

?

Basic Specification:
Channel Width Up to 200m
Water Depths Up to 20m, subject to channel width
No. of Velocity Paths Up to 32
Overall Accuracy

2%-5% of flow reading, depending on site conditions

Datalogging 1MB capacity. Sampling interval 30secs to 30mins
Power Supply Options?? 12V or 24V DC, 85-264V AC with internal battery for standby operation.
Outputs Various analog and digital options
Communications RS232 for PC or modem
Software Windows-based? for setup, diagnostics, data download