Product Focus
SITRANS Probe LU
2 Wire Ultrasonic transmitter for Level and Flow Measurement.
2-wire, loop powered ultrasonic transmitter for level, volume, and flow. Highly intelligent with single push button obstruction avoidance and HART & Profibus options, ideal for devolved measurement into existing or new control solutions. With the highest of Ingress protection the LU Probe is a low cost solution suitable for a wide variety of applications. ATEX and 6m and 12m range options.
Innovative Solutions Include ..
The appraisal of the technical capability of an instrumentation and measurement company and it's engineering, is the combination of their knowledge, experience, and skills displayed in their ability to select, install, commission and test the most appropriate and effective instrumentation and measurement system that ..
Read More >>
Latest News
3 in a Row with Scottish Water
Processplus are pleased to announce their third consecutive term in support of Scottish Water's ongoing capital program, 2010-2015. In partnership…
Read More >>
Our range of Aluminium analyser systems are extremely versatile and suitable for on-line measurement in a range of applications. Processplus offer a suitable selection of devices as well as supporting you with extensive application expertise. Our portfolio includes user-friendly and highly reliable systems using colorimetric chemistry, single and multi stream measurements with background colour correction and automatic self cleaning after every measurement. With up to 6-off analogue and alarm relay outputs these systems also provide trending, SD storage, Ethernet connectivity and optional Profibus DP V1.0 connectivity.
Aluminium analyser systems are generally found in the monitoring of Iron based coagulants used in potable water treatment.
Basic Specification:
| Range | 0-1.500ppm |
| Accuracy | <5% or 0.005ppm |
| Repeatability | <5% of reading |
| Calibration | 2-point, automatic, user selectable interval |
| Sample Flow | 200-500ml/min continuous; 5psi maximum |
| Sample Limitations | Particles 100um and greater may require pre-filtration |
| Power | 90 to 264 VAC, 18 to 36 VDC optional |